Add to Cart
2*4 2.0/3.0mm Yellow Jacket Fiber Optic Y Cable Coupler Module With Connector
Application
Long-haul,Metro and Access System
Fiber CATV and Fiber Network System
Specification
Optic and/or electric specificatioin
Parameter |
Specification |
Unit |
Note |
|
Operating Wavelength |
1260~1360&1471~1611 |
nm |
/ |
|
Nominal Coupling Ratio |
50/50 |
|||
IL |
COMMON IN→OUT-1 |
≤4.1 |
dB |
|
COMMON IN→OUT-2 |
||||
IN-1→COMMON OUT |
||||
IN-2→COMMON OUT |
||||
PDL |
≤0.2 |
dB |
||
Uniformity |
≤0.7 |
dB |
||
Return Loss |
≥55 |
dB |
||
Directivity |
≥55 |
dB |
NOTE: All the data above include the loss of connectors.
Operation/storage temperature/humidity
Parameter |
Specification |
Unit |
Note |
Operating temperature |
-20 ~ +70 |
°C |
|
Operation Humidity |
5~95 |
%RH |
|
Storage temperature |
-40~+85 |
°C |
|
Storage Humidity |
5~95 |
%RH |
|
Power Handling |
500 |
mW |
Features
Low Insertion Loss,High Return Loss
Good repeatability and Interchangeability
Description
Optical Fiber Y Cable is the cable with twisted Connectors terminated on its ends respectively to release the jumping connection of light patch.
PIgtail and connector
Parameter |
Specification |
Unit |
Note |
Fiber Pigtail |
SMF-28e+ 1.8mm duplex tube, LSZH |
||
Fiber Length(All Ports) |
See below table |
||
Connectors |
COMMON:Simplex-LC/APC 180-degree boot IN&OUT:Simplex-LC/PC 45-degree boot |
||
Dimension |
φ13*130 |
mm |